Advanced Search
    ZHAO Jinlan, TONG Ke, LI Hong, GUO Jun, LIU Jianxiong, LIU Qing. Burst Cause of 140V Steel Grade Production Casing Pipe During Wellbore Pressure Test[J]. Materials and Mechanical Engineering, 2022, 46(11): 97-101. DOI: 10.11973/jxgccl202211016
    Citation: ZHAO Jinlan, TONG Ke, LI Hong, GUO Jun, LIU Jianxiong, LIU Qing. Burst Cause of 140V Steel Grade Production Casing Pipe During Wellbore Pressure Test[J]. Materials and Mechanical Engineering, 2022, 46(11): 97-101. DOI: 10.11973/jxgccl202211016

    Burst Cause of 140V Steel Grade Production Casing Pipe During Wellbore Pressure Test

    • The 140 V steel grade production casing pipe bursted during the wellbore pressure test. The causes of the casing pipe burst were analyzed by macromorphology analysis, geometry measurement, mechanical test, metallographic examination, scanning electron microscopy and energy spectrum analysis and so on. The results show that the microstructure, geometric size, mechanical properties and internal pressure strength of the failed casing met the requirements of the standard. The burst mode of the pipe was ductile fracture. The main reason for the burst was that the internal pressure of the pipe exceeded its own pressure bearing capacity, resulting in the overload fracture.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return